Gas relay (also known as gas relay) is a protective device used by the transformer. It is installed in the pipeline between the oil conservator and the oil tank of the transformer. When the internal fault of the transformer decomposes the oil to produce gas or causes oil flow surge, the contact of the gas relay acts, connects the specified control circuit, and sends out signal alarm (light gas) in time Or start the protection element to automatically cut off the transformer (heavy gas).

Light gas is mainly reflected in operation or slight fault. The gas decomposed by oil rises into the gas relay, the air pressure decreases the oil level, the open cup of the relay falls with the oil level, and the light gas dry spring contact is connected to send a signal. When there is too much gas in the light gas, the gas can be discharged by the gas nozzle of the gas relay.

The heavy gas is mainly reflected in the strong gas generated by the serious internal fault of the transformer (especially the fault that other transformer protection cannot act quickly such as inter turn short circuit) to push the oil flow to impact the baffle. The magnet on the baffle attracts the heavy gas dry spring contact to make the contact connected and trip.

The gas relay is divided into on load gas relay (the radius of oil pipe is generally 50mm or 80mm) and body gas relay (the radius of oil pipe is generally 80mm). There are different models of gas relay, such as float type, baffle type, open cup type and so on. For example, the signal circuit of qj-80 relay is connected to the open cup, and the tripping circuit is connected to the lower baffle. The so-called gas protection signal action means that the signal circuit contact of the upper open cup in the relay is closed and the light plate light is on due to various reasons.

Differential pressure controller: jc3.5 0.05-0.35mpa differential pressure controller, jc3.5fs differential pressure controller, cwk-22 0.1-0.4mpa differential pressure controller, cwk-11 0.1-0.5mpa differential pressure controller, jc0535 0.05-0.35mpa differential pressure controller, jy616 0.6-1.6mpa differential pressure controller, ywk-22 differential pressure controller, d520 / 7dd differential pressure controller, d520 / 7ddk differential pressure controller

Temperature controller: D530 / 7dd temperature controller, D530 / 7ddk temperature controller, D540 / 7T temperature controller, D540 / 7tk temperature controller, d541 / 7T temperature controller

Temperature relay: xu-200 temperature relay, jw2 temperature relay, jw4 temperature relay, jvc-1m temperature relay, jvc-3m temperature relay

Pressure sensor: cy1 pressure sensor, cyo pressure sensor

Gas relay: qj1-80 gas relay, qj1-50 gas relay, qj4-50 gas relay, qj4-80 gas relay

Oil flow relay: yj-50 oil flow relay, yj-80 oil flow relay, yj-150 oil flow relay

Speed relay: JY-1 2A / 500V speed relay

The company also supplies similar products of the above products: qj1-50 qj4-80 gas relay

2、 Product use and parameters

Purpose: qj-50 gas relay (hereinafter referred to as relay) is a protection device for oil immersed transformer with oil conservator and on load voltage regulating switch. The relay is installed in the connecting pipeline between the transformer, on load voltage regulating switch oil tank and oil conservator

Technical parameters:

Oil flow speed range and factory setting value of tripping contact action

model QJ1-80 QJ1-50 QJ1-25

Velocity range 0.7-1.5m/s 0.6-1.0m/s 1.0m/s

Factory setting 1.0m/s 0.8m/s 1.0m/s

1. Relay pipeline diameter:

Qj1-25 is ф 25, qj1-5o is ф 50, qj1-80 is ф eighty

2. Operating temperature of relay: - 30 ℃ - + 95 ℃

3. Signal contact action gas capacity: 250-300cm3

4. Rated contact capacity: 220V 0.3A, 110V 0.6A (s 5x10 s)

5. Insulation strength: 2000V / NIM

6. Sealing performance: the relay is filled with transformer oil and pressurized at room temperature for 200KPa / 20min without leakage.